Thermo King MAGNUM PLUS®

Call for Price


Availability
Brochure
Manufacturer
Thermo King
Model
MAGNUM PLUS®

Overview

Description

The MAGNUM PLUS® became the industry standard when it raised the bar for reefer efficiency, performance, operability and reliability. Featuring the MP-4000 controller and efficient scroll compressor, MAGNUM PLUS® provides an industry-low -40 C set point, fast pull down, a homogenous floor spread and the tightest temperature control available.

Features
  • Lowest Temperature
  • Fast Pull-Down
  • Precise Temperature Control
  • Low Energy Consumption
  • Proven Technology
Standard Features
  • R-404A refrigerant
  • Scroll Compressor with Digital Control Valve for capacity modulation, economizer circuit, ambient compensated internal overload and high temperature protection
  • Proportional-integral differential ( PID )
  • Refrigeration capacity control system
  • Non-corrosive maritime construction, which includes a marine-treated aluminum alloy frame, non-corrosive fittings, stainless steel hardware, condenser coil with epoxy e-coat and polyurethane top coat for UV protection, hydrophilic coating on evaporator coil, and a marine duty protective coating on the compressor
  • Condenser and evaporator fan motors, which include stainless steel shafts and internal thermal overload protection
  • CFC-free, foamed-in-place insulation
  • Wired for 380/460 volt, three-phase, 50/60 Hz power supply with an 18 meter (60 ft) 11/4 power cable with CEE-17 plug
  • Bottom air discharge
  • Automatic electronic phase correction system 29 Vac control system
  • On-demand defrost combined with intelligent timed defrost
  • Manual defrost with initiation via MP-4000
  • Indicator lights, which include Alarm, Alarm acknowledges, in range, and approaching in range
  • Time delay start sequence
  • Composite condenser and evaporator fans
  • Conforms to ISO classifications and specifications for thermal containers, including : racking and endloading standards, TIR specifications, ATP refrigeration standards, ARI standards for rating refrigeration capacity, UIC international Union of Railways, Australian Electrical Certification, British Standard 3755 Requirement ( TAINT ), USDA requirements for “ Insect Cold ” treatment, and Agrotechnological Research Institute ( ATO-DLO ) for flower bulb transportation
  • Auxiliary battery and charger
  • USDA “ Cold Treatment ” provision
Options
  • AFAM + Advanced Fresh Air Exchange Management
  • Water Cooler Condenser
  • Thermo King electronic chart recorder
  • Partlow temperature recorder
  • Saginomiya Temperature recorder
  • Remote monitoring
  • Transfresh provision
  • 10/4 power cable
  • De-humidification control
System Net Cooling Capacity - Full Cool
  • Return air to evaporator coil inlet: 21.1 °C (70 F) 60 Hz: 54,000 BTU/hr; 16,603 kW; Power Consumption: 11.55 kW
  • Return air to evaporator coil inlet: 1.7 °C (35 F) 60 Hz: 42,000 BTU/hr; 11,990 kW; Power Consumption: 11 kW
  • Return air to evaporator coil inlet: -17.8 °C (0 F) 60 Hz: 25,000 BTU/hr; 7,300 kW; Power Consumption: 7.3 kW
  • Return air to evaporator coil inlet: -28.9 °C (-20 F) 60 Hz: 17,300 BTU/hr; 5,000 kW; Power Consumption: 6.6 kW
  • Return air to evaporator coil inlet: -35 °C (-31 F) 60 Hz: 14,000 BTU/hr; 4,100 kW; Power Consumption: 6 kW
  • Return air to evaporator coil inlet: -40 °C (-40 F) 60 Hz: 12,636 BTU/hr; 3,700 kW; Power Consumption: 3.7 kW
Dimensions
  • Height: 2,235 mm (88 in.)
  • Width: 2,026 mm (79.8 in.)
  • Depth: 420 mm (16.5 in.)
  • Weight: 397 Kg (875 lb)
System Net Heating Capacity
  • 460/230V, 3 Phase, 60 Hz Power: 5,250 Watts; 4,515 Kcal/hr; 17914 BTU/hr
  • 380/190V, 3 Phase, 50 Hz Power: 3,900 Watts; 3,353 Kcal/hr; 13,300 BTU/hr