(713) 671-2700
Search
Home
Home
Products
Pre-Owned
Links List
Staff
About Us
Contact Us
Locations
Specials
Account
CARB Compliant?
Pheonix Global Parts
Services
Parts Order Form
|
New Units
New Units
Factory Promotions
|
Parts
|
Pre-Owned
|
Specials
|
Staff
|
About Us
|
Locations
Locations
San Antonio Thermo King
Thermo King of South Texas
Thermo King of Laredo
Thermo King of Austin
Thermo King of Houston
|
Contact Us
Product Categories
Red Dot
Condensors
Filter and Pressurizers
Heater
Heater - Air Conditioner
Hydraulic Compressors
Multi - Use
Thermo King
Bus
Container
Heating & Freeze Protection
Rail
Small Truck
Trailer
TriPac APU
Truck
Showcase Product Detail
Audio
Accounts
Products
Images
Products
»
Thermo King
» ShuttleAire S-30 II
Model Quick Search
- Brand -
Red Dot
Thermo King
- Type -
Bus
Container
Heating & Freeze Protection
Rail
Small Truck
Trailer
TriPac APU
Truck
- Year -
- All -
2009
Call for Price
(713) 671-2700
Thermo King ShuttleAire S-30 II
Request a Quote
Financing Calculator
Request a Brochure
Request a Quote
Financing Calculator
Request a Brochure
OEM Overview
Specifications
Compare Models
Current Promotions
Overview
A complete product line to meet a wide range of applications including: small buses, vans, ambulances, security vehicles and special purpose vehicles
Supported by the industry's largest worldwide service organization
Engineered for reliability, low maintenance and high performance for the life of the vehicle
Heavy duty fin and tube coils.
R-134a refrigerant
Specifications
Cooling Capacity Version 1000 : (Cool only)
Cooling Capacity : Rated: 24908 BTU/hr (7.3 kWatts) Maximum: 30026 BTU/hr (8.8 kWatts)
Cooling Capacity 1004: Version 1004 (Cool and Heat)
Cooling Capacity 1004: Version 1004 has 9% less cooling capacity than standard version 1000
Refrigerant: R-134a
Ambient : Rated: 35 deg. C (95 deg. F) Maximum: 49 deg. C (120.2 deg. F)
Interior Dry Temperature : 27 deg. C (80.6 deg. F) 49 deg. C (120.2 deg. F)
Interior Wet Temperature : 19 deg. C (66.2 deg. F) 26 deg. C (78.8 deg. F)
Compressor TM16 RPM: 4000 r/min.
Heating Capacity (system 1004 only): Rated: 12.3 kWatts Maximum: 41967.8 BTU/hr
Heating Capacity: Coolant Mixture: 50% water, 50% ethylene glycol
Heating Capacity: Coolant Temp. Inlet: Rated: 90 deg. C Maximum: 194 deg. F
Heating Capacity: Return Air Temperature: Rated: 11.3 l/min Maximum: 60.1 deg. F
Heating Capacity: Coolant Flow: Rated: 11.3 l/min Maximum: 3.0 GPM
Air Flow: At 0 mm water external pressure
Air Flow Evap/Heater: High Speed: Rated: 1408 m³/h Maximum: 829CFM
Air Flow Evap/Heater: Middle Speed: Rated: 968 m³/hr Maximum: 570 CFM
Air Flow Evap/Heater: Low Speed: Rated: 793 m³/hr Maximum: 467 CFM
Air Flow Condenser: Rated: 2139 m³/h Maximum: 1259 CFM
Refrigerant / Charge: R-134a / 8.6 lbs (3.9 kg)
Maximum Operating Temperature: Rated: 49 deg. C Maximum: 120.2 deg. F
Voltage: 13.5 / 27 V DC
Current (max.): Total: 1000 Version: 49 / 25 1004 Version: 50 / 26
Current (max.) Evaporator: 26 / 13
Current (max.) Condenser: 19 / 10
Current (max.) Boost Pump: 1004 Version: 1.2 / 0.6 A
Current (max.) Compressor Clutch: 4 / 2 A
Weight Evaporator: 1000 Version: 61.7 lbs (28 kg) 1004 Version: 50.7 lbs (23 kg)
Weight Evaporator (low-profile): 1000 Version: 70.5 lbs (32 kg)
Weight Condenser Undermount: 70.5 lbs (32 kg)
Weight Condenser Undermount (low-profile): 63.9 lbs (29 kg)
Weight Condenser Rooftop: 90.4 lbs (41 kg)
Weight Compressor TM16 with Clutch: 15.7 lbs (7.1 kg)
Dimensions: Evaporator: Length: 42.5 in. (1080 mm) Width: 21.1 in. (535 mm) Height: 8.8 in. (224 mm)
Dimensions: Evaporator (low-profile): Length: 59.2 in. (1504 mm) Width: 18.6 in. (473 mm) Height: 6.5 in. (165 mm)
Dimensions: Condenser Undermount: Length: 43.3 in. (1100 mm) Width: 15.6 in. (397 mm) Height: 12.3 in. (313 mm)
Dimensions: Condenser Undermount (low-profile): Length: 45.7 in. (1160 mm) Width: 5.2 in. (184 mm) Height: 12.3 in. (313 mm)
Dimensions: Condenser Rooftop: Length: 48.8 in. (1240 mm) Width: 40.2 in. (1020 mm) Height: 5.4 in. (138 mm)
Specifications
Capacities
Cooling Capacity
Rated: 24908 BTU/hr (7.3 kWatts) Maximum: 30026 BTU/hr (8.8 kWatts)
Heating Capacity
Rated: 12.3 kWatts Maximum: 41967.8 BTU/hr
Airflow
Airflow Volume
Air Flow Evap/Heater: High Speed: Rated: 1408 m³/h Maximum: 829CFM; Air Flow Evap/Heater: Middle Speed: Rated: 968 m³/hr Maximum: 570 CFM; Air Flow Evap/Heater: Low Speed: Rated: 793 m³/hr Maximum: 467 CFM; Air Flow Condenser: Rated: 2139 m³/h Maximum: 1259 CFM
General
Weight
Weight Evaporator: 1000 Version: 61.7 lbs (28 kg) 1004 Version: 50.7 lbs (23 kg); Weight Evaporator (low-profile): 1000 Version: 70.5 lbs (32 kg); Weight Condenser Undermount: 70.5 lbs (32 kg); Weight Condenser Undermount (low-profile): 63.9 lbs (29 kg); Weight Condenser Rooftop: 90.4 lbs (41 kg); Weight Compressor TM16 with Clutch: 15.7 lbs (7.1 kg)
Dimensions
Dimensions: Evaporator: Length: 42.5 in. (1080 mm) Width: 21.1 in. (535 mm) Height: 8.8 in. (224 mm); Dimensions: Evaporator (low-profile): Length: 59.2 in. (1504 mm) Width: 18.6 in. (473 mm) Height: 6.5 in. (165 mm); Dimensions: Condenser Undermount: Length: 43.3 in. (1100 mm) Width: 15.6 in. (397 mm) Height: 12.3 in. (313 mm); Dimensions: Condenser Undermount (low-profile): Length: 45.7 in. (1160 mm) Width: 5.2 in. (184 mm) Height: 12.3 in. (313 mm); Dimensions: Condenser Rooftop: Length: 48.8 in. (1240 mm) Width: 40.2 in. (1020 mm) Height: 5.4 in. (138 mm)
Compare Models
- Year -
2009
- Manufacturer -
- Style -
- Model -
- Year -
2009
- Manufacturer -
- Style -
- Model -
Year
2009
Manufacturer
Thermo King
Model
ShuttleAire S-30 II
Airflow
Airflow Volume
Air Flow Evap/Heater: High Speed: Rated: 1408 m³/h Maximum: 829CFM; Air Flow Evap/Heater: Middle Speed: Rated: 968 m³/hr Maximum: 570 CFM; Air Flow Evap/Heater: Low Speed: Rated: 793 m³/hr Maximum: 467 CFM; Air Flow Condenser: Rated: 2139 m³/h Maximum: 1259 CFM
Discharge Velocity (airthrow)
Capacities
Cooling Capacity
Rated: 24908 BTU/hr (7.3 kWatts) Maximum: 30026 BTU/hr (8.8 kWatts)
Heating Capacity
Rated: 12.3 kWatts Maximum: 41967.8 BTU/hr
General
Weight
Weight Evaporator: 1000 Version: 61.7 lbs (28 kg) 1004 Version: 50.7 lbs (23 kg); Weight Evaporator (low-profile): 1000 Version: 70.5 lbs (32 kg); Weight Condenser Undermount: 70.5 lbs (32 kg); Weight Condenser Undermount (low-profile): 63.9 lbs (29 kg); Weight Condenser Rooftop: 90.4 lbs (41 kg); Weight Compressor TM16 with Clutch: 15.7 lbs (7.1 kg)
Dimensions
Dimensions: Evaporator: Length: 42.5 in. (1080 mm) Width: 21.1 in. (535 mm) Height: 8.8 in. (224 mm); Dimensions: Evaporator (low-profile): Length: 59.2 in. (1504 mm) Width: 18.6 in. (473 mm) Height: 6.5 in. (165 mm); Dimensions: Condenser Undermount: Length: 43.3 in. (1100 mm) Width: 15.6 in. (397 mm) Height: 12.3 in. (313 mm); Dimensions: Condenser Undermount (low-profile): Length: 45.7 in. (1160 mm) Width: 5.2 in. (184 mm) Height: 12.3 in. (313 mm); Dimensions: Condenser Rooftop: Length: 48.8 in. (1240 mm) Width: 40.2 in. (1020 mm) Height: 5.4 in. (138 mm)
Current Promotions
There are currently no promotions available for this product.
Request a Quote
[x]
Product Information
Year:
2009
Manufacturer:
Thermo King
Model:
Thermo King ShuttleAire S-30 II
*First Name:
*Email:
*Phone:
Address 1:
City:
Postal Code:
*Last Name:
*Confirm Email:
Country:
United States
Canada
Argentina
Aruba
Australia
Austria
Bahamas
Barbados
Belgium
Bermuda
Bolivia
Brazil
British West Indies
Cayman Islands
Chile
China
Colombia
Costa Rica
Cyprus
Czech Republic
Denmark
Dominican Republic
Ecuador
Egypt
England
Finland
France
Germany
Great Britain
Greece
Greenland
Guam
Hong Kong
Hungary
Iceland
India
Indonesia
Ireland
Israel
Italy
Jamaica
Japan
Jordan
Kuwait
Latvia
Lebanon
Malaysia
Malta
Mexico
Monaco
Morocco
Netherlands
Netherlands Antilles
New Caledonia
New Zealand
Nigeria
Norway
Pakistan
Panama
Peru
Philippines
Poland
Portugal
Puerto Rico
Qatar
Russia
SAR, China
Saudi Arabia
Singapore
South Africa
South Korea
Spain
Sweden
Switzerland
Taiwan
Thailand
Trinidad and Tobago
Turkey
United Arab Emirates
United Kingdom
Uruguay
US Virgin Islands
Venezuela
Vietnam
West Indies
Ukraine
Address 2:
Region:
Alabama
Alaska
Arizona
Arkansas
Armed Forces Americas
Armed Forces Europe
Armed Forces Pacific
California
Colorado
Connecticut
D.C.
Delaware
Florida
Georgia
Hawaii
Idaho
Illinois
Indiana
Iowa
Kansas
Kentucky
Louisiana
Maine
Maryland
Massachusetts
Michigan
Minnesota
Mississippi
Missouri
Montana
Nebraska
Nevada
New Hampshire
New Jersey
New Mexico
New York
North Carolina
North Dakota
Ohio
Oklahoma
Oregon
Pennsylvania
Rhode Island
South Carolina
South Dakota
Tennessee
Texas
Utah
Vermont
Virgin Islands
Virginia
Washington
West Virginia
Wisconsin
Wyoming
Purchase Time-frame:
Immediate
1 Week
1 Month
2 Months
3 Months
4 Months
5 Months
6 Months
7 Months
8 Months
9 Months
10 Months
11 Months
1 Year
How did you find our Web site?
---Select One---
Search Engines
TV
Radio
Newspaper
Word of mouth
Manufacturer locator
Yellow Pages
Billboard
Other
Comments (limit 500 characters):
*Trade Manufacturer:
*Trade Model:
*Years Owned:
*Trade Year:
Trade Condition:
Excellent
Good
Fair
Poor
*Required fields.
Request a Brochure
[x]
Product Information
Year:
2009
Manufacturer:
Thermo King
Model:
Thermo King ShuttleAire S-30 II
*First Name:
*Email:
*Address 1:
*City:
*Country:
United States
Canada
Argentina
Aruba
Australia
Austria
Bahamas
Barbados
Belgium
Bermuda
Bolivia
Brazil
British West Indies
Cayman Islands
Chile
China
Colombia
Costa Rica
Cyprus
Czech Republic
Denmark
Dominican Republic
Ecuador
Egypt
England
Finland
France
Germany
Great Britain
Greece
Greenland
Guam
Hong Kong
Hungary
Iceland
India
Indonesia
Ireland
Israel
Italy
Jamaica
Japan
Jordan
Kuwait
Latvia
Lebanon
Malaysia
Malta
Mexico
Monaco
Morocco
Netherlands
Netherlands Antilles
New Caledonia
New Zealand
Nigeria
Norway
Pakistan
Panama
Peru
Philippines
Poland
Portugal
Puerto Rico
Qatar
Russia
SAR, China
Saudi Arabia
Singapore
South Africa
South Korea
Spain
Sweden
Switzerland
Taiwan
Thailand
Trinidad and Tobago
Turkey
United Arab Emirates
United Kingdom
Uruguay
US Virgin Islands
Venezuela
Vietnam
West Indies
Ukraine
*Last Name:
*Confirm Email:
Address 2:
*Region:
Alabama
Alaska
Arizona
Arkansas
Armed Forces Americas
Armed Forces Europe
Armed Forces Pacific
California
Colorado
Connecticut
D.C.
Delaware
Florida
Georgia
Hawaii
Idaho
Illinois
Indiana
Iowa
Kansas
Kentucky
Louisiana
Maine
Maryland
Massachusetts
Michigan
Minnesota
Mississippi
Missouri
Montana
Nebraska
Nevada
New Hampshire
New Jersey
New Mexico
New York
North Carolina
North Dakota
Ohio
Oklahoma
Oregon
Pennsylvania
Rhode Island
South Carolina
South Dakota
Tennessee
Texas
Utah
Vermont
Virgin Islands
Virginia
Washington
West Virginia
Wisconsin
Wyoming
*Postal Code:
*Required fields.
Financing Calculator
[x]
Loan Amount
Loan Length in Months
Interest Rate (%)
Monthly Payment
Calculated $:
Annual Payment
Calculated $:
Thank You
[x]
Request Submitted
Thank you for your interest, your brochure request will be processed promptly.
Find OEM Parts
[x]
Find Aftermarket Products
[x]
All Brands
Promo
x
of
x
All Brands
Loading...
View Promotion Details
|
View All Promotions
Factory Promotions
Hours
M-F
8:00 a.m.
5:00 p.m.
Emergency Service
We offer 24 hour emergency service on Saturdays and Sundays.